Thicknesses and dimensions of 4 through 64 ductile iron pipe conform to ansi awwa c151 a21. The bolt is specially designed for rugged water works applications. Awwa m41 manual ductileiron pipe and fittings, third edition. This standard covers the thickness design of ductile iron pipe complying with the requirements of ansiawwa c151 a21. Ductile iron pipe standards and suggested specifications dipra. Ductile iron pipe, centrifugally cast for water and other liquids ansi a21. Awwa standards describe minimum requirements and is not a specification. This standard establishes minimum requirements for rubberseated butterfly valve assemblies, 78 in. Length lb fastite and mjfab mj and mjfab flexring and mjfab 1514 350. You open up any part of your water system for maintenance or repairs. Ductile iron fittings shall conform to the latest revision of awwa c110ansi a21. Pdf awwa standard ductileiron pipe, centrifugally cast. Centrifugally casting for water standard meet ansiawwa c151a21. The purpose of this standard is to provide purchasers, manufacturers, and constructors with the minimum requirements for rubbergasket joints for ductileiron pressure pipe and fittings, including materials, design, inspection, testing, marking, and shipping.
One of the most important reasons for the success of ductile iron pipe is that, like gray iron pipe before it, it is the subject of the most extensive series of product standards in the pipe industry. American ductile iron specials american fabricated mechanical. In this 2012 release, important changes had been implemented which increased the design safety factors of several critical gate components, compared to previous versions of the same standard. My other dog played along and he became intrigued now its a daily part of our routine about 3 times a day we do the shell game and the muffin tin game. Joints, unless otherwise specified, shall be of the pushon type conform ing to ansi a21. Obxc 0620 mu1 the orbinox model mu is a 4 sided sealing slide gate.
Certification of compliance mcwane ductile certifies that all products furnished by mcwane ductile comply with all applicable provisions and latest revisions of the following standards. Ufgs 33 32 16 packaged utility wastewater pumping stations. In 2012 however, the committee on slide gates had approved a major revision of c561. The gates are suitable for different types of applications with a highly versatile flow control for waste water treatment plants, irrigation, hydraulic works and hydro. The 25point scoring method of spickelmire 2002 is similar scheme as the awwa 10point method except that many other factors are included. When pipe is cut in the field, the cut end may be readily.
Water storage tanks disinfecting a potable water storage tankthat is, a tank used for storing drinking waterin accordance with standards set by the american water works association awwa can be a difficult task. Design considerations are provided in awwa m23, pvc pipedesign and installation, which provides detailed information on pvc pipe covered by ansiawwa c905. Established in 1881, the american water works association is the oldest and largest nonprofit, scientific and educational organization dedicated to safe and sustainable water in the world. In fact, most pipe furnished is cement lined, providing improved flow characteristics and the required protection against internal corrosion. Ductile iron pipe shall have a cement mortar lining and an internal seal coat in accordance with awwa c. Ductile iron pipe standards and suggested specifications.
Chlorination dechlorination proceduresa new twist to an old technologyrobert gordhamer measurement technologies, inc. This product can expose you to chemicals including lead, which is known to the state of california to cause cancer and birth defects or other reproductive harm. American ductile iron specials american fabricated mechanical joint pipe ansiawwa c151 a21. Mu slide gates orbinox reserves the right to change specifications without notice. The manual shall include procedures for handling emergency calls and repairs. Ductile iron pipe shall be according to awwa c151 a21. Ductile iron pipe and fittings shall be cement lined according to awwa c104 a21. This standard describes shopapplied cementmortar linings specified in the ansi awwa c100 a21 series of standards for ductileiron pipe and ductileiron and grayiron fittings for potable water.
Pipe material ductile iron, gray iron notes fittings conform to ansi a21. Awwaansi c65105 disinfecting water mains first standard approved sept. The major revisions in this edition of ansi awwa c151 a21. Cementlined pipe is also furnished for some sewage service and a number of other applications. Awwa c90615 is a comprehensive update to the standard that includes signi. This standard describes the thickness design of ductileiron pipe complying with the requirements of ansi awwa c151 a21. Unless youre looking to get into the tank cleaning business, you might consider leaving this project up to a professional. Nov 05, 2015 update on ace i have gotten him involved in playing some of the games and i can see a difference in his confidence already. In order to read a secure pdf, you will need to install the fileopen plugin on your computer. Corrosion control ductile iron pipe research association. Supplied with rigid radius grooves in accordance with ansiawwa c606 connects pipe, provides change in direction, and adapts sizes or components. Excellent impact resistance is confirmed by tests made at regular intervals in accordance with ansiawwa c151a21. Design basis the basis of the design standard for ductile iron pipe is the long established fact that ductile iron pipe, subjected to. Awwa standard ductileiron pipe, centrifugally cast.
American ductile iron specials american fabricated. Th e awwa standards committee on polyvinyl chloride pressure pipe and fittings, which. This one page downloadable pdf file outlines a sample specification for. The cast iron pipe century club recognizes utilities with cast iron pipe that has provided continuous service for 100 years or more. This standard covers the thickness design of ductile iron pipe complying with the requirements of ansi awwa c151 a21. Awwa standards describe minimum requirements and do not contain all of the engineering and administrative information normally. Ductileiron pipe and fittings awwa manual m41 this manual provides both technical and general information to aid in the design, specification, procurement, installation, and understanding of ductile iron pipe and fittings. Pipe shall be cementmortar lined per ansi awwa c104 a21.
Requirements for awwa tank disinfection by erik price hunker may earn compensation through affiliate links in this story. No more thorough and comprehensive standard design procedure exists for any piping material. Your water system is contaminated with coliform bacteria. With approximately 50,000 members, awwa provides solutions to improve public health. The american waterworks association awwa issued the updated ansiawwa c65114 standard, disinfecting water mains on february 1, 2015,as a result of. Includes an outline of the design procedure and an example with the basis of design or design method. Update on ace i have gotten him involved in playing some of the games and i can see a difference in his confidence already. Awwa c51614 largediameter rubberseated butterfly valves, sizes 78 in. All ductile iron pipe shall conform to awwa c 151 ansi a 21. Appendices of awwa c110, c111, and c115 or approved equal.
Ductile iron compact fittings 3inch diameter through 16inch diameter for water ansi a21. American water works association awwa awwa about established in 1881, the american water works association is the largest nonprofit, scientific and educational association dedicated to managing and treating water, the worlds most important resource. The update incorporates high performance pe4710 resins that improve the durability and reliability of hdpe pressure pipe used in potable water systems. Ductile iron pipe has superseded cast iron pipe, but dipra continues to sponsor the cast iron pipe century club as a salute to utilities for a job well done. All pipe is to have a standard water works cement mortar lining in accordance with awwa standard c104 with outside coating per section 51. It is intended for use by utilities and municipalities of all sizes, as well as, design engineers and consultants. American national standard for ductileiron pipe, centrifugally cast, for water this standard covers 3in. Contractor shall submit an emergency repair manual prepared and furnished by the pipe manufacturer. Fittings with flange joints are not covered by this standard for sizes 3 in. Emergency disinfection of small water systems 331242 revised 2172020 you should provide emergency disinfection when. Since the 1920s, american national standards institutenow the american water works associationstandards committee a21. With more than 50,000 members worldwide and 43 sections in north america, awwa advances public health, safety and welfare by uniting the efforts of the. Coating and lining outside coating shall be an asphaltic coating approximately one mil thick. Rubber gaskets for pushon or mechanical joints shall be according to awwa c111 a21.
1455 547 956 1344 1171 734 1134 648 1362 721 626 91 640 925 978 350 1285 878 1480 1028 1421 408 1182 68 845 845 663 331 1356 1318 339 331 995 1010 130 1285